Air Heat Exchanger Cleaning
- Make sure that the machine is oil drained before cleaning the air heat exchanger (see Oil and Oil Filter Change).
- Run the machine without oil and at atmospheric pressure for a maximum of 1 minute to drain the radiator.
- Make sure to protect the open hydraulic connections to avoid contamination.
Description
1
Use compressed air and wear protective eyewear and mask
2
2x O-ring, see "Service kit" (chapter Spare Parts)
3
13 mm wrench / max. admissible torque: 20Nm