Discharge Connection
CAUTION
The discharge gas contains small quantities of oil.
Risk to health!
- If air is discharged into rooms where persons are present:
- Make sure that sufficient ventilation is provided.
NOTICE
Discharge gas flow obstructed.
Risk of damage to the machine !
- Make sure that the discharged gas will flow without obstruction. Do not shut off or throttle the discharge line or use it as a pressurized air source.
Connection size(s):
- G2” (with optional exhaust flange)
- 2" NPT (with optional exhaust flange)
Unless the aspirated air is discharged to the environment right at the machine.
- Make sure that the discharge line either slopes away from the machine or provide a liquid separator or a siphon with a drain cock, so that no liquids can flow back into the machine.
- Make sure that the connection lines cause no stress on the connections of the machine. Therefore, we recommend installing flexible joints on the suction and discharge connections.