Installation Conditions

NOTICE

Use of the machine outside of the permitted installation conditions.

Risk of premature failure!

Loss of efficiency!

  1. Make sure that the installation conditions are fully respected.

Description

1

Standard version

2

Version with cooling air deflector (optional)

  1. Make sure that the environment of the machine is not potentially explosive.
  2. Make sure that the ambient conditions comply with the Technical Data.
  3. Make sure that the environmental conditions comply with the protection class of the motor and the electrical elements.
  4. Make sure that the installation space or location is protected from weather and lightning.
  5. Make sure that the installation space or location is vented such that sufficient cooling of the machine is provided.
  6. Make sure that cooling air inlets and outlets are not covered or obstructed and that the cooling air flow is not affected adversely in any other way.
  7. Make sure that the oil sight glass (OSG) remains easily visible.
  8. Make sure that enough space remains for maintenance work.
  9. Make sure that the machine is placed or mounted horizontally, a maximum deviation of 1° in any direction is acceptable.
  10. Even 0.5° in longitudinal direction, in case of a level switch is being used in.
  11. Check the oil level, see Oil Level Inspection.
  12. Make sure that all provided covers, guards, hoods, etc. are mounted.

Version with water-oil heat exchanger:

  1. Make sure that the cooling water complies with the requirements, see Cooling Water Connection (Optional).

If the machine is installed at an altitude greater than 1000 meters above sea level:

  1. Contact your Busch representative, the motor should be derated or the ambient temperature limited.

If the machine is equipped with monitoring devices or sensors:

  1. Make sure that the monitoring devices are correctly connected and integrated into a control system such that operation of the machine will be inhibited if the safety limit values are exceeded, see Electrical Connection of the Monitoring Devices.