Conveying Condensable Vapors

CAUTION

caution

Draining the condensate while operating and/or venting the machine, the discharged gases and/or liquids may reach temperatures above 70°C.

Risk of burns!

  1. Avoid direct contact with the gas and/or liquid stream.

CAUTIONcaution

Noise of running machine.

Risk of damage to hearing!

  1. If people are present in the vicinity of a machine that is not insulated from noise for extended periods of time:
  1. Make sure to wear hearing protection.

Water vapor within the gas flow is tolerated within certain limits. The conveyance of other vapors shall be agreed upon with Busch.

If condensable vapors are to be conveyed:

START

  1. Close the isolation valve* and open the gas ballast valve** (GB)
  2. Warm up the machine for 30 minutes
  3. Open the isolation valve* and perform the process
  4. Close the isolation valve*
  5. Wait 30 minutes
  6. Close the gas ballast valve** (GB)

END

* Not included in the scope of delivery.

** Can be considered as optional on some products