Pressure Relief Lines Maintenance
(Gas Tight Version Only)
WARNING
Media potentially dangerous.
Risk of poisoning!
Risk of infection!
- Wear appropriate personal protective equipment in case of high concentration of the medium in the ambient atmosphere of the machine.
- Check that pressure relief lines (PRL) are not clogged as described in the following illustrations.
Description
1
Unscrew nuts
2
Blow into the pipe
NOTICE
Pressurized air systems supply too high pressure.
Risk of damage to the machine!
- Adjust the pressurized air to 0.2 bar(g) by means of a pressure regulator.
In case of clogged pressure relief lines (PRL):
- Remove the clogging or have the machine repaired (contact Busch).
Description
1
Unscrew plugs
2
Connect pressurized air to the pressure relief lines
3
Air pressure max. 0.2 bar (g)
4
Tighten plugs
Description
1
Tighten nuts