Discharge Connection
Description | |||
---|---|---|---|
1 | Discharge variants (without silencer) |
NOTICE
Discharge gas flow obstructed.
Risk of damage to the machine!
- Make sure that the discharged gas will flow without obstruction. Do not shut off or throttle the discharge line or use it as a pressurized air source.
Connection size(s):
At the machine discharge connection:
- G3, horizontal (orientable 180°)
- ISO DN100, DIN 28404, vertical (without discharge elbow)
At the silencer (SI) discharge connection (Optional):
- ISO DN100, DIN 28404, horizontal
- Make sure that the connection lines cause no stress on the connections of the machine. Therefore, we recommend installing flexible joints on the suction and discharge connections.
- Make sure that the counter pressure (also called “back pressure”) at the discharge connection (OUT) does not exceed the maximum allowable discharge pressure, see Technical Data.