Barrier Gas System Connection (Optional)
Description | |||||||
---|---|---|---|---|---|---|---|
BGC | Barrier gas connection | FME | Flow meter | ||||
MAN | Manometer | PRV | Pressure regulating valve |
- Connect the barrier gas connection (BGC) to the gas supply.
Connection size:
- G1/4, ISO 228-1
- Make sure that the gas complies with the following requirements:
Gas type | Dry nitrogen or air | |
Gas temperature | °C | 0 ... 60 |
Maximum gas pressure | bar (g) | 13 |
Recommended pressure setting at the pressure regulating valve (PRV) | bar (g) | 3 |
Filtration | µm | 5 |
Recommended flow rate | SLM (standard liter per minute) | 15 ... 20 |
Air quality (only for air) | Acc. to ISO 8573-1 | Class 5.4.4. |