Technical Data

NX 0950 A WCV

Pumping speed (72Hz)

m³/h

950

ACFM

560

Ultimate pressure
(without gas ballast)

hPa (mbar) abs.

≤0.01

TORR

≤0.0075

Ultimate pressure
(with gas ballast)

hPa (mbar) abs.

≤0.05

TORR

≤0.0375

Nominal motor rating

kW

18.5

HP

25

Nominal motor speed (72Hz)

min-1

4320

RPM

4320

Max. intensity

A

35

Circuit breaker (MCCB)

A

C-50 (SCCR 10kA @ 400V)

Noise level (EN ISO 2151)

dB(A)

≤75

Ambient temperature range

°C

5 … 40

°F

41 … 104

Max. allowable counter pressure at the discharge

hPa (mbar) rel.

200

TORR

150

Max. allowable gas inlet temperature according to the inlet pressure

°C

≤50 hPa (mbar) abs. ► 200

>50 hPa (mbar) abs. ► 70

°F

≤37.5 Torr ► 392

>37.5 Torr ► 158

Relative humidity

at 30°C

90%

at 86°F

90%

Ambient pressure

Atmospheric pressure

Cooling water requirements

See Cooling Water Connection

Oil capacity - motor side

L

1

qts.

1.05

Oil capacity - suction side

L

1

qts.

1.05

Weight approx.

Kg

900

Lbs.

2000